• Heating, Cooling, Air Conditioning, Furnace, Installation, Repair, Ameren Core Ally, Home Depot Service Provider

  • Ameren IL Core Ally
    Home Depot Service Provider
    CALL US

    (618) 477-8337

    1350 Grand Ave., Madison, IL 62060

  • Spring AC Tune-up

  • THE VALUE TO YOU!

  • Condenser Coil

    fins will be straightened and cleaned as required.

    Value to You

    Dirty condenser coils raise refrigerant pressure higher than needed, increasing your electrical bill.
  • Evaporator Coil

    will be inspected and cleaned as required.

    Value to You

    Evaporator coils become dirty because air filter only collect a portion of the particles in the air. Even a small amount of dirt can decrease efficiency and increase operating costs. This is also a major cause of compressor failure. Customer should replace properly sized air filter every month.
  • Blower Wheels

    will be inspected and cleaned as necessary.

    Value to You

    Dirty blower wheels reduce airflow, causing longer operating time and increased cost. This problem can lead to lost comfort and compressor failure.
  • Refrigerant Charge

    checked by super heat/subcooling method.

    Value to You

    A low or high refrigerant charge can easily go unnoticed and increase operating costs. An improper charge can cause compressor shutdown.
  • Air Filter

    will be replaced at customer's option.

    Value to You

    A restricted air filter can cause your air conditioning unit to waste energy and shorten the compressor's life.
  • Thermostat

    will be checked and calibrated as required.

    Value to You

    Improperly calibrated thermostats allow the unit to run longer than necessary. every degree your air conditioning operates below 78 degrees can add 5 to 8% to the cost of cooling.

  • Capacitors

    will be tested.

    Value to You

    Bad capacitors can lead to compressor and motor failure.
  • Relays and Contactors

    will be inspected.

    Value to You

    Worn contacts and loose wire connection can lead to a motor or compressor failure.
  • Condensate Drain

    will be checked to assure it is open

    Value to You

    Algae can plug a condensate drain which can cause expensive water damage.
  • Unit Disconnect

    will be inspected.

    Value to You

    A worn or over heated disconnect blows fuses and is dangerous.

  • Unit Wiring

    will be inspected and loose connections tightened.

    Value to You

    Loose connections can lead to a motor or compression failure.
  • Temperatures and Pressures

    will be taken and recorded.

    Value to You

    An accurate record of your equipment's vital data can indicate potential problems, which can be eliminated. A record will be kept with the unit which may reduce emergency service time.